CY7C1381D
CY7C1383D
Document #: 38-05544 Rev. *E Page 24 of 29
ZZ Mode Timing
[29, 30]
Notes:
29. Device must be deselected when entering ZZ mode. See truth table for all possible signal conditions to deselect the device.
30. DQs are in high-Z when exiting ZZ sleep mode.
Timing Diagrams (continued)
t
ZZ
I
SUPPLY
CLK
ZZ
t
ZZREC
LL INPUTS
(except ZZ)
DON’T CARE
I
DDZZ
t
ZZI
t
RZZI
Outputs (Q)
High-Z
DESELECT or READ Only