Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature .................................–65°C to +150°C
Ambient Temperature with
Power Applied.............................................–55°C to +125°C
Supply Voltage to Ground Potential............... –0.5V to +7.0V
DC Input Voltage............................................ –0.5V to +7.0V
Output Current into Outputs (LOW).............................64 mA
Static Discharge Voltage...........................................> 2001V
(per MIL-STD-883, Method 3015)
Latch-up Current.....................................................> 200 mA
Operating Range
Range Ambient Temperature V
CC
Commercial 0°C to +70°C 3.3V ± 10%
Electrical Characteristics Over the Operating Range
[5]
Parameter Description Test Conditions
CY7B9911V
UnitMin. Max.
V
OH
Output HIGH Voltage V
CC
= Min., I
OH
= –18 mA 2.4 V
V
OL
Output LOW Voltage V
CC
= Min., I
OL
= 35 mA 0.45 V
V
IH
Input HIGH Voltage (REF and FB inputs only) 2.0 V
CC
V
V
IL
Input LOW Voltage (REF and FB inputs only) –0.5 0.8 V
V
IHH
Three-Level Input HIGH Voltage (Test, FS,
xFn)
[6]
Min. ≤ V
CC
≤ Max. 0.87 * V
CC
V
CC
V
V
IMM
Three-Level Input MID Voltage (Test, FS,
xFn)
[6]
Min. ≤ V
CC
≤ Max. 0.47 * V
CC
0.53 * V
CC
V
V
ILL
Three-Level Input LOW Voltage (Test, FS,
xFn)
[6]
Min. ≤ V
CC
≤ Max. 0.0 0.13 * V
CC
V
I
IH
Input HIGH Leakage Current (REF and FB
inputs only)
V
CC
= Max., V
IN
= Max. 20 µA
I
IL
Input LOW Leakage Current (REF and FB
inputs only)
V
CC
= Max., V
IN
= 0.4V –20 µA
I
IHH
Input HIGH Current (Test, FS, xFn) V
IN
= V
CC
200 µA
I
IMM
Input MID Current (Test, FS, xFn) V
IN
= V
CC
/2 –50 50 µA
I
ILL
Input LOW Current (Test, FS, xFn) V
IN
= GND –200 µA
I
OS
Short Circuit Current
[7]
V
CC
= MAX, V
OUT
= GND (25° only) –200 mA
I
CCQ
Operating Current Used by Internal Circuitry V
CCN
= V
CCQ
= Max., All
Input Selects Open
Com’l 95 mA
Mil/Ind 100
I
CCN
Output Buffer Current per Output Pair
[8]
V
CCN
= V
CCQ
= Max.,
I
OUT
= 0 mA Input Selects Open, f
MAX
19 mA
PD Power Dissipation per Output Pair
[9]
V
CCN
= V
CCQ
= Max.,
I
OUT
= 0 mA Input Selects Open, f
MAX
104 mW
Notes:
5. See the last page of this specification for Group A su/jointfilesconvert/478599/bgroup testing information.
6. These inputs are normally wired to V
CC
, GND, or left unconnected (actual threshold voltages vary as a percentage of V
CC
). Internal termination resistors hold
unconnected inputs at V
CC
/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional t
LOCK
time
before all data sheet limits are achieved.
7. CY7B9911V should be tested one output at a time, output shorted for less than one second, less than 10% duty cycle. Room temperature only.
8. Total output current per output pair can be approximated by the following expression that includes device current plus load current:
CY7B9911V:I
CCN
= [(4 + 0.11F) + [[((835 –3F)/Z) + (.0022FC)]N] x 1.1
Where
F = frequency in MHz
C = capacitive load in pF
Z = line impedance in ohms
N = number of loaded outputs; 0, 1, or 2
FC = F < C
9. Total power dissipation per output pair can be approximated by the following expression that includes device power dissipation plus power dissipation due to
the load circuit:
PD = [(22 + 0.61F) + [[(1550 + 2.7F)/Z) + (.0125FC)]N] x 1.1
See note 8 for variable definition.
10. Applies to REF and FB inputs only. Tested initially and after any design or process changes that may affect these parameters.