Cypress Semiconductor STK14C88-3 Bedienungsanleitung Seite 6

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 5
AN55662
October 5, 2009 Document No. 001-55662 Rev. ** 6
Power Up Recall Related Improvements
Additional parameters are specified in CY14B256LA such as
HSB
Output Disable Voltage (V
HDIS
),
HSB
To Output Active
Time (t
LZHSB
), and
HSB
High Active Time (t
HHHD
) which helps in system design. Refer to Figure 3 and Figure 4 for the definition
of the additional specs in power up. Also, note that
HSB
remains low until the end of the power up in the new part. This would
guard against the system inadvertently thinking the part has completed the boot up prior to real completion.
Figure 3. STK14C88-3: Power Up Recall
Figure 4. CY14B256LA: Power Up Recall
[+] Feedback
Seitenansicht 5
1 2 3 4 5 6 7 8

Kommentare zu diesen Handbüchern

Keine Kommentare