EZ-USB FX2 Technical Reference Manual v2.1 Appendix C - 28
EZ-USB FX2 Registers & Buffers
E682 1 WAKEUPCS Wakeup Control & Status WU2 WU WU2POL WUPOL 0 DPEN WU2EN WUEN xx000101 bbbbrbbb
E683 1 TOGCTL Toggle Control Q S R IO EP3 EP2 EP1 EP0 00000000 rbbbbbbb
E684 1 USBFRAMEH USB Frame count H 0 0 0 0 0 FC10 FC9 FC8 00000xxx R
E685 1 USBFRAMEL USB Frame count L FC7 FC6 FC5 FC4 FC3 FC2 FC1 FC0 xxxxxxxx R
E686 1 MICROFRAME Microframe count, 0-7 0 0 0 0 0 MF2 MF1 MF0 00000xxx R
E687 1 FNADDR USB Function address 0 FA6 FA5 FA4 FA3 FA2 FA1 FA0 00000000 R
E688 2 reserved
ENDPOINTS
E68A 1 EP0BCH Endpoint 0 Byte Count H (BC15) (BC14) (BC13) (BC12) (BC11) (BC10) (BC9) (BC8) xxxxxxxx RW Even though the EP0 buffer is
only 64 bytes, the EP0 byte
count is expanded
to 16-bits to allow using the
Autoptr with a custom length,
instead of USB-
dictated length (from Setup
Data Packet and number of
requested bytes).
The byte count bits in paren-
theses apply only when SD-
PAUTO = 0
E68B 1 EP0BCL Endpoint 0 Byte Count L (BC7) BC6 BC5 BC4 BC3 BC2 BC1 BC0 xxxxxxxx RW
E68C 1 reserved
E68D 1 EP1OUTBC Endpoint 1 OUT Byte Count 0 BC6 BC5 BC4 BC3 BC2 BC1 BC0 0xxxxxxx RW
E68E 1 reserved
E68F 1 EP1INBC Endpoint 1 IN Byte Count 0 BC6 BC5 BC4 BC3 BC2 BC1 BC0 0xxxxxxx RW
E690 1 EP2BCH
see Section 15.14
Endpoint 2 Byte Count H 0 0 0 0 0 BC10 BC9 BC8 00000xxx RW EP2,6 can be 512 or 1024
EP4,8 are 512 only
E691 1 EP2BCL
see Section 15.14
Endpoint 2 Byte Count L BC7 BC6 BC5 BC4 BC3 BC2 BC1 BC0 xxxxxxxx RW
E692 2 reserved
E694 1 EP4BCH
see Section 15.14
Endpoint 4 Byte Count H 0 0 0 0 0 0 BC9 BC8 000000xx RW
E695 1 EP4BCL
see Section 15.14
Endpoint 4 Byte Count L BC7 BC6 BC5 BC4 BC3 BC2 BC1 BC0 xxxxxxxx RW
E696 2 reserved
E698 1 EP6BCH
see Section 15.14
Endpoint 6 Byte Count H 0 0 0 0 0 BC10 BC9 BC8 00000xxx RW
E699 1 EP6BCL
see Section 15.14
Endpoint 6 Byte Count L BC7 BC6 BC5 BC4 BC3 BC2 BC1 BC0 xxxxxxxx RW
E69A 2 reserved
E69C 1 EP8BCH
see Section 15.14
Endpoint 8 Byte Count H 0 0 0 0 0 0 BC9 BC8 000000xx RW
E69D 1 EP8BCL
see Section 15.14
Endpoint 8 Byte Count L BC7 BC6 BC5 BC4 BC3 BC2 BC1 BC0 xxxxxxxx RW
E69E 2 reserved
E6A0 1 EP0CS Endpoint 0 Control and Status HSNAK 0 0 0 0 0 BUSY STALL 10000000 bbbbbbrb
E6A1 1 EP1OUTCS Endpoint 1 OUT Control and
Status
0 0 0 0 0 0 BUSY STALL 00000000 bbbbbbrb
E6A2 1 EP1INCS Endpoint 1 IN Control and Sta-
tus
0 0 0 0 0 0 BUSY STALL 00000000 bbbbbbrb